Diagnostics
To use diagnostics, you must import corresponding classes and include a list of diagnostics in the Simulation:
from lcode.simulation import Simulation
from lcode.diagnostics import FXiDiag, FXiType, OutputType, ParticlesDiag
from lcode.diagnostics import SliceDiag, SliceType, SliceValue
sim = Simulation(config=config, diagnostics = [Diag1(...), Diag2(...), ...])
This section will describe what can be transferred to the diagnostics list.
Note
You can use several diagnostics of the same type, but be sure to specify a different directory_name for each.
FXiDiag
These keys control output of various quantities as functions of \(\xi\), either in the form of a graph, or in the form of a data array.
- class lcode.diagnostics.FXiDiag(output_period, saving_xi_period, f_xi, output_type, probe_lines, directory_name)
output_period (default: 100)
saving_xi_period (default: 100)
f_xi (default: FxiType.Ez)
output_type (default: OutputType.NUMBERS)
probe_lines (default: 0)
directory_name (default: None)
output_period
The period at which the diagnostics is triggered. If ∆tout < ∆t, then the diagnostics is called at each time step.
saving_xi_period
The period in \(\xi\) at which data is dumped to disk.
Warning
This property is experimental. Choosing a small value may slow down program execution.
f_xi
Selecting a value to output.
FXiType.E
: All components of the electric field. You can also select the component you want to display by using Ex, Ey, Ez, Er, Ef instead of E.FXiType.B
: All components of the magnetic field. You can also select the component you want to display by using Bx, By, Bz, Bf instead of B.FXiType.n
: Electron and ion density of the plasma. You can also select the component you want to display by using ne or ni instead of n.FxiType.rho_beam
: Charge density of the beam.FxiType.Phi
: Wakefield potential (currently only works in 3D).
FXiType
is imported from lcode.diagnostics
.
Note
You can combine any values: FxiType.Ez | FxiType.Bx | FxiType.n
output_type
Data output format. It can be OutputType.NUMBERS
, OutputType.PICTURES
or OutputType.ALL
, where OutputType
is imported from lcode.diagnostics
.
OutputType.NUMBERS
: Output data in the form of numpy structured array.OutputType.PICTURES
: Output data in the form of png plots.OutputType.ALL
: Two above options at once.
probe_lines
Selecting an offset in x, y (r for 2D) from the axis.
Use a number, list or np.ndarray.
When using the number x, the resulting shift is (x, 0) [or x in r for 2D].
When using a one-dimensional array [x1, x2, …], the diagnostics will output data for shifts (x1, 0), (x2, 0), … [or x1, x2, … for 2D].
When using a two-dimensional array [[x1, y1], [x2, y2], …], diagnostics will output data for shifts (x1, y1), (x2, y2), … [or \(r_i = \sqrt{x_i^2 + y_i^2}\) for 2D].
directory_name
Select the folder in which the diagnostics will be saved. By default, the files will be saved in the diagnostics/
folder. When you specify the example
directory_name, the files will be saved along the diagnsotics/example/
path.
SliceDiag
These keys control output of various quantities as functions of 2 coordinates, either in the form of a colored map, or in the form of a data array.
- class lcode.diagnostics.SliceDiag(slice_type, slice_value, output_type, limits, offset, output_period, saving_xi_period, directory_name)
slice_type (default: SliceType.XI_X)
slice_value (default: SliceValue.Ez)
output_type (default: OutputType.NUMBERS)
limits (default: [[0, inf], [-inf, inf]])
offset (default: 0)
output_period (default: 100)
saving_xi_period (default: 100)
directory_name (default: None)
slice_type
Selecting a plane (2 coordinates) for output.
SliceType.XI_X
SliceType.XI_Y
SliceType.X_Y
SliceType.XI_R
[Equivalent to XI_X]
SliceType
is imported from lcode.diagnostics
.
slice_value
Selecting a value to output.
SliceValue.E
: All components of the electric field. You can also select the component you want to display by using Ex (Ey, Ez, Er, Ef) instead of E.SliceValue.B
: All components of the magnetic field. You can also select the component you want to display by using Bx (By, Bz, Bf) instead of B.SliceValue.n
: Electron and ion density of plasma. You can also select the component you want to display by using ne (ni) instead of n.SliceValue.rho_beam
: Density of beam.SliceValue.Phi
: Wake potential. (currently only works in 3D)
SliceValue
is imported from lcode.diagnostics
.
Note
You can combine any values: SliceValue.Ez | SliceValue.Bx | SliceValue.n
output_type
Data output format. It can be OutputType.NUMBERS
, OutputType.PICTURES
or OutputType.ALL
, where OutputType
is imported from lcode.diagnostics
.
OutputType.NUMBERS
: Output data in the form of numpy structured array.OutputType.PICTURES
: Output data in the form of png plots.OutputType.ALL
: Two previous points at the same time.
limits
Selecting a subwindow for output. By default, the entire window is displayed.
You need to use a two-dimensional list, np.ndarray like [[from1, to1], [from2, to2]]. Where 1 and 2 are the coordinates corresponding to the SliceType
.
If you go beyond the limits, the limit will be returned to the window border.
offset
Responsible for shifting from the axis along a coordinate that is not specified in SliceType.
For example, offset set to x for slice XI_X means x shift along the Y coordinate.
output_period
The period with which the diagnosis is triggered. If ∆tout < ∆t, then diagnostics will be called at every step.
saving_xi_period
The intermediate period with which data is flushed to disk.
Warning
This property is experimental. Changing it may slow down program execution.
directory_name
Select the folder in which the diagnostics will be saved. By default, the files will be saved in the diagnostics/
folder. When you specify the example
directory_name, the files will be saved along the diagnsotics/example/
path.
ParticlesDiag
Output plasma and beam particles
- class lcode.diagnostics.SliceDiag(slice_type, slice_value, output_type, limits, offset, output_period, saving_xi_period, directory_name)
save_beam (default: false)
save_plasma (default: false)
output_period (default: 100)
saving_xi_period (default: 100)
directory_name (default: None)
save_beam
If set to true, beam_<t>.npz
files are output to diagnostics/directory_name
every output_period
.
save_plasma
If set to true, plasma_electrons_<t>.npz
(and plasma_ions_<t>.npz
for movable ions) files are output to diagnostics/directory_name
every output_period
.
output_period
The period with which the diagnosis is triggered. If ∆tout < ∆t, then diagnostics will be called at every step.
saving_xi_period
The intermediate period with which plasma state is flushed to disk into diagnostic/snapshot
folder.
directory_name
Select the folder in which the diagnostics will be saved. By default, the files will be saved in the diagnostics/
folder. When you specify the example
directory_name, the files will be saved along the diagnsotics/example/
path.